All products will be exposed to a variety of climatic conditions over the use of the product life. A given product may be exposed to a variety of environmental extremes from the time the product is manufactured, packaged, transported, and stored until it reaches its final destination.

We offer CTS Gmbh’s range of environmental testing products which are used to simulate these conditions to find product flaws before the product reaches the customer – saving substantial warranty and product recalls.  There are many models available.

Climatic Test Chambers

  • Test chamber volume: 60, 200, 350, 600, 1000, 1500 litres
  • Temperature ranges:
  • +10°C to +180°C
  • -20°C to +180°C
  • -40°C to +180°C
  • -70°C to +180°C (optional -75°C)
  • Climate ranges :10% to 98% relative humidity (rel. hum.)
  • Temperature fluctuation : ± 0,1 to ± 0,3 Kelvin temporary
  • Dew point range : +5°C to 89,5°C
  • Deeper dew points as options
  • Humidity Fluctuations :
  • ±1% to ±2% rel. hum. under 90% rel. hum.
  • ±1% to ±3% rel. hum. above 90% rel. hum

Shock Test Chambers

  • Test chamber volume : 32litres, 130 litres and 350 litres
  • Temperature ranges : Heat chamber +50°C to +220°C (+250°C)
  • Cold chamber :-70°C to -10°C
  • Extremely high rates of increase and decrease for the temperature
  • Compliance with the actually valid test standards
  • Lift cage drive with spindle-type gear mechanism
  • Temperature probe in lift cage, as well as further measuring and supply lines, to be installed from the top, using leadthrough

Temperature Test Chambers

  • Test chamber volume :25, 50, 100, 200, 350, 600, 1000, 1500 litres
  • Temperature ranges :
  • -20°C to +180°C
  • -40°C to +180°C
  • -70°C to +180°C (optional -75°C)
  • Temperature fluctuation : ± 0,1 to ± 0,3 Kelvin temporary
  • High rates of increase and decrease for the temperature according to DIN 50011 part 12 (>20 K/mim)

Stress Screen Options

  • Test cabinet volume : 25, 50, 100, 200, 350, 530, 900 litres and special sizes
  • Temperature ranges :
    -40°C to +180°C
    -70°C to +180°C

Rates of increase and decrease for the temperature according to DIN 50011 part 12 up to > 20 K/min